Jimmy John's - #2180
B7000 N 16th St, Phoenix 85020
Food Establishment - Eating & Drinking · Permit FD-23-02207
Score based on 3 scored inspections over the county's rolling 3-year window, weighted toward recent visits. How scoring works
Score over time
Inspection history3 on record
2026
Mar 2, 2026Routine1 priorityall corrected on siteB
No County legal action will result from this inspection.
Inspector's notes
Observed y-valve with shut-off valves installed on mop sink faucet equipped with atmospheric vacuum breaker. Shut-offs, including chemical dispensers and sprayer nozzles, are not approved for continuous installation downstream from atmospheric vacuum breakers. Person in charge removed shut-off downstream from atmospheric vacuum breaker at time of inspection. Corrective Action: Corrected at time of inspection.
Show full county text
PRIORITY VIOLATION-5-202.11 (A) - Priority: Approved System and Cleanable Fixtures; According to Law
2025
Sep 30, 2025RoutinecleanA°
No County legal action will result from this inspection.No violations noted at time of inspection.
2023
Dec 6, 2023Routine2 priority2 foundation2 coreC°
This establishment is not participating in the award program at this time and had _ Priority, _ Priority Foundation and _ Core Violations on this inspection.Inspection emailed to Nicolas at time of inspectionBusiness card providedNo County legal action will result from this inspectionReinspection scheduled for Dec 20Award: Not Participating,Food Manager Licenses: 0,Review Complete: CHECKED,Review Notes: QA ML,Signer: Nicolas Q
Priority Foundation-5-203.11, Pf: Handwashing Sinks-Numbers and Capacities. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4573/AMC-Toolbox---Handwashing. --- No handwash station in the back area where the ice machine is located. The only handwash station is located in the front service area. Ice machine around corner behind a wall in the office area between the mopsink and the desk --- Provide handwash station. Handwash stations are to be within 25 ft from any point of food handling, clearly visible with no physical barriers Correct By: Correct Prior To Reinspection
PRIORITY VIOLATION-7-202.12, P: Conditions of Use -- Facility has a can of Raid Insect Spray that is stored in the utensil bin with the funnel and utensils on the back wire shelf unit --- employee removed RAID can from the facility, facility required to have licensed pest control, educated on storage of chemicals and proper pest control, storage bin and utensils placed at three compartment sink to be warewashed Correct By: Corrected At Time Of Inspection
Core-6-202.15, C: Outer Openings, Protected -- Back door damaged on bottom of the door that a 1 inch tall and 2 inches wide is missing --- repair or replace door, provide protection from outside Priority Foundation-6-501.111 (C), Pf: Controlling Pests; Approved Trapping Methods/Existence -- Facility has fruit flies that are in the front warewashing area and in the back area --- provide licensed pest control, reinspection scheduled, have pest control receipt available or inspection sheet at time of reinspection :
Core-4-204.120, C: Equipment Compartments, Drainage -- facility only has two of the three required drain plugs for the three compartment sink -- obtain and utilize all three drain plugs for the setup of the three compartment sink, ie -- wash, rinse and sanitize (no pre-rinsing in the middle compartment while three compartment sink is setup for warewashing) Correct By: Correct Prior To Next Routine Inspection
PRIORITY VIOLATION-5-205.15 (A), P: System Maintained in Good Repair; According to Law --- Facility has installed a chemical dispenser (shut off valves) downstream of the atmospheric vacuum breaker (non-continuous backflow preventer) at the mopsink --- provide separate water line for the chemical dispenser, no shut off valves are allowed downstream of noncontinuous backflow preventers Chemical dispenser has ASSE 1055B backflow preventer installed that is not approved --- provide ASSE 1055A backflow at mopsink chemical dispenser Facility has a ASSE1022 backflow for the soda machine -- provide ASSE 1013 reduced pressure backflow preventer Womens restroom faucet and three compartment sink faucet leak -- repair/replace and maintain in good condition Facility has drainage lies laying on the floor sink grate -- provide 1 inch air gap from drainage line to the top of the floor sink flood lip :
Core-6-501.11, C: Repairing-Premises, Structures, Attachments, and Fixtures-Methods -- Facility has a hole in the middle of the grease trap lid --- repair/replace and Core-6-201.16, C: Wall and Ceiling Coverings and Coatings --- Ceiling tile missing over the hot water heater -- provide ceiling tile over the hot water heatermaintain in good condition Correct By: Correct Prior To Next Routine Inspection
Data from Maricopa County Environmental Services public records, last checked Jul 20, 2026. Grades marked with ° are computed equivalents for establishments not participating in the county's voluntary grading program. View official county records →