PlateScore

Subway #10996

A

8248 W Deer Valley Rd, Peoria 85383

Food Establishment - Eating & Drinking · Permit FD-24-00807

Score based on 7 scored inspections over the county's rolling 3-year window, weighted toward recent visits. How scoring works

78
Good

Peoria restaurant avg: 97

Compare with another

Score over time

100060202420252026Feb 29, 2024 — Routine — score 59 (2 priority, 2 foundation, 1 core)Aug 29, 2024 — Routine — score 49 (3 priority, 1 foundation, 1 core)Sep 17, 2024 — Re-Inspection — score 44 (3 priority, 2 foundation, 1 core)Jun 10, 2025 — Re-Inspection — score 34 (4 priority, 1 foundation, 1 core)Dec 2, 2025 — Routine — score 95 (0 priority, 1 foundation, 0 core)Dec 5, 2025 — Re-Inspection — score 100 (0 priority, 0 foundation, 0 core)Apr 13, 2026 — Routine — score 98 (0 priority, 0 foundation, 2 core)98
Score per routine inspection and re-inspection; dashed line marks the “Poor” threshold (60).

Inspection history7 on record

2026

Apr 13, 2026Routine2 coreA

Predefined Comment: No County legal action will result from this inspection.Reviewed facility's procedures and protocols for:--Certified Food Protection Manager (i.e. - on site during operating hours)

#45 — Single-Use/Single-Service Articles; Properly Stored, UsedCore4-903.12

Inspector's notes

Single service equipment and/or utensils found stored under drain line of front counter hand sink. Cleaned and sanitized equipment, utensils, laundered linens, and single service and single-use articles may not be stored in locker rooms; in toilet rooms; in garbage rooms; in mechanical rooms; under sewer lines that are not shielded to intercept potential drips; under leaking water lines including leaking automatic fire sprinkler heads or under lines on which water has condensed; under open stairwells; or under other sources of contamination. PIC relocated equipment at time of inspection. Corrective Action: Corrected at time of inspection.

Show full county text

4-903.12 - Core: Prohibitions; Single-Use/Single-Service Items

#55 — Physical Facilities Installed, Maintained, and CleanCore6-501.12

Inspector's notes

Residue buildup found in floor drain servicing soda fountain machine.

Show full county text

6-501.12 - Core: Cleaning, Frequency and Restrictions Predefined Comment: Physical facility must be cleaned frequently enough to prevent accumulation of dirt, organic matter, and food debris. Clean physical facility prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.

2025

Dec 5, 2025Re-InspectioncleanA°

Priority violations documented on 12/2/25 have been verified corrected through electronic means on 12/5/254. A copy of this report is emailed to the responding email.

Dec 2, 2025Routine1 foundationB

Predefined Comment: No County legal action will result from this inspection.

#10 — Adequate Handwashing Sinks, Properly Supplied and AccessiblePriority foundation6-301.12

Inspector's notes

No soap or paper towels at the back handsink. Instructed person in charge to provide soap within 10 days and to email picture showing as such.

Show full county text

6-301.12 - Priority Foundation: Hand Drying Provision. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4573/AMC-Toolbox: Handwashing. 6-301.11 - Priority Foundation: Handwashing Cleanser, Availability. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4573/AMC-Toolbox: Handwashing.

Jun 10, 2025Re-Inspection4 priority1 foundation1 coreD°

Due to the violations noted on this inspection report, County legal action may result from this inspection.Re-Inspection - E&D Class 3. This inspection was conducted with the manager on duty. A PDF copy of this inspection report was emailed to Josh B. at the time of this inspection. All listed violations must be corrected prior to re-inspection. Re-inspection is scheduled for 07/08/2025.

#22 — Proper Cold Holding TemperaturesPriority3-501.16

Inspector's notes

1. Measured the temperature of containers of chicken and deli meats being held at 50°F in the undercounter prep refrigerator in the front area. All TCS foods were removed from this refrigerator during the inspection. Corrective Action: Corrected at time of inspection.

Show full county text

Repeat Violation PRIORITY VIOLATION-3-501.16(A)(2) and (B) - Priority: Time/Temperature Control for Safety Food, Cold Holding. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you.https://www.maricopa.gov/4576/AMC-Toolbox---Cold-Holding.

#33 — Proper Cooling Methods Used; Adequate Equipment for Temperature ControlPriority foundation4-301.11

Inspector's notes

1. Measeured the temperature of containers of chicken and deli meats being held at 50°F in the undercounter prep refrigerator in the front area. All TCS foods were removed from this refrigerator during the inspection. TCS food items have been measured out of temperature in this unit on 02/29/2024, 08/29/2024, 09/17/2024 and 06/10/2026. A condemned sticker was placed on the front of the unit. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation 4-301.11 - Priority Foundation: Cooling, Heating, and Holding Capacities-Equipment. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4617/AMC-Toolbox---Cooling.

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-205.15

Inspector's notes

1. The food prep sink is currently draining directly into the mop sink basin. The drain pipe for the food prep sink must not drain directly into the mop sink basin. Provide an NSF approved food prep sink that has a hard piped drain line that empties indirectly into a floor sink with a minimum 1 in. air-gap between the end of the drain pipe and the flood rim of the floor sink. 2. Provide a rigid drain line for the sump pump that currently drains the condensate from the walk-in units into the floor sink below the 3-compartment sink. Ensure there is a 1-inch air gap between the end of the drain line and the flood rim of the floor sink. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation PRIORITY VIOLATION-5-205.15 (A) - Priority: System Maintained in Good Repair; According to Law

#52 — Sewage and Waste Water Properly DisposedPriority5-402.13

Inspector's notes

1. The portion of the drain pipe for the three compartment sink that is directly connected to the sewer system is still leaking onto the floor beneath the three compartment sink. All the basins for the three compartment sink must drain indirectly into the floor sink with minimum 1 in. air-gaps and the direct connection must be eliminated and properly capped off and sealed. Corrective Action: Correct prior to re-inspection. PRIORITY VIOLATION-5-402.11 - Priority: Backflow Prevention Addl Notes: 1. Two of the three compartments of the three compartment sink are currently connected directly to the sewer system. Reroute the drain pipes from all three basins of the three compartment sink to empty into the nearby floor sink. There must minimum 1 in. air-gaps between the ends of all drain pipes and the flood rim of the floor sink they drain into. Corrective Action: Correct prior to re-inspection.

Show full county text

PRIORITY VIOLATION-5-402.13 - Priority: Conveying Sewage

#56 — Adequate Ventilation and Lighting; Designated Areas UsedCore6-303.11

Inspector's notes

1. Replace the very dim light in the walk-in refrigerator. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation 6-303.11 - Core: Intensity-Lighting

2024

Sep 17, 2024Re-Inspection3 priority2 foundation1 coreD°

Due to the violations noted on this inspection report, County legal action may result from this inspection.Re-Inspection - E&D Class 3 This inspection was conducted with the manager on duty. A PDF copy of this inspection report was emailed to Jennifer R. at the time of this inspection. All listed violations must be corrected prior to re-inspection. Re-inspection is scheduled for 10/01/2024.

#22 — Proper Cold Holding TemperaturesPriority3-501.16

Inspector's notes

1. Measured the temperature of containers of chicken and deli meats being held at 56°F in the undercounter prep refrigerator in the front area. All TCS foods were removed from this refrigerator during the inspection. Corrective Action: Corrected at time of inspection.

Show full county text

Repeat Violation PRIORITY VIOLATION-3-501.16(A)(2) and (B) - Priority: Time/Temperature Control for Safety Food, Cold Holding. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you.https://www.maricopa.gov/4576/AMC-Toolbox---Cold-Holding.

#33 — Proper Cooling Methods Used; Adequate Equipment for Temperature ControlPriority foundation4-301.11

Inspector's notes

1. Measeured the temperature of containers of chicken and deli meats being held at 56°F in the undercounter prep refrigerator in the front area. All TCS foods were removed from this refrigerator during the inspection. This unit must be repaired to maintain foods at 41°F or less. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation 4-301.11 - Priority Foundation: Cooling, Heating, and Holding Capacities-Equipment. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4617/AMC-Toolbox---Cooling.

#50 — Hot and Cold Water Available; Adequate PressurePriority foundation5-103.11

Inspector's notes

1. There is still only a 38 gallon capacity water heater installed. Provide a minimum 50 gallon capacity water heater as indicated on your inspection reports dated 03-31-2024 and 08-29-2024. Corrective Action: Correct prior to re-inspection.

Show full county text

5-103.11 - Priority Foundation: Capacity-Quantity and Availability

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-202.13

Inspector's notes

1. The food prep sink is currently draining directly into the mop sink basin. The drain pipe for the food prep sink must not drain directly into the mop sink basin. Provide an NSF approved food prep sink that has an indirect , hard piped drain line that empties indirectly into a floor sink with a minimum 1 in. air-gap between the end of the drain pipe and the flood rim of the floor sink. 2. The middle and left compartmens of the three compartment sink are currently connected directly to the sewer system. Reroute the drain pipes from these two basins so that they empty into the floor sink with minimum 1 in. air gaps like the right compartment currently does. 3. Provide a rigid drain line for the sump pump that currently drains the condensate from the walk-in units into the floor sink below the 3-compartment sink. Ensure there is a 1-inch air gap between the end of the drain line and the flood rim of the floor sink. The drain line is currently extending down into the floor sink. 4. There is a water leak and standing water in the cabinet beneath the self-service soda station. Repair all water leaks and clean the inside of this cabinet. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation PRIORITY VIOLATION-5-202.13 - Priority: Backflow Prevention, Air Gap

#52 — Sewage and Waste Water Properly DisposedPriority5-402.13

Inspector's notes

1. The portion of the drain pipe for the three compartment sink that is directly connected to the sewer system is still leaking onto the floor beneath the three compartment sink. All the basins for the three compartment sink must drain indirectly into the floor sink with minimum 1 in. air-gaps and the direct connection must be eliminated and properly capped off and sealed. Corrective Action: Correct prior to re-inspection.

Show full county text

PRIORITY VIOLATION-5-402.13 - Priority: Conveying Sewage

#56 — Adequate Ventilation and Lighting; Designated Areas UsedCore6-303.11

Inspector's notes

1. Replace the very dim light in the walk-in refrigerator. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation 6-303.11 - Core: Intensity-Lighting

Aug 29, 2024Routine3 priority1 foundation1 coreD

Due to the violations noted on this inspection report, County legal action may result from this inspection.Routine Inspection - E&D Class 3This inspection was conducted with the manager on duty.A PDF copy of this inspection report was emailed to Jennifer R. at the time of this inspection.Re-inspection is scheduled for 09/17/2024.

#22 — Proper Cold Holding TemperaturesPriority3-501.16

Inspector's notes

1. Measured the temperature of containers of Tuna and deli meats being held at 47°F in the undercounter prep refrigerator in the front area. All TCS foods were removed from this refrigerator during the inspection. Corrective Action: Corrected at time of inspection.

Show full county text

Repeat Violation PRIORITY VIOLATION-3-501.16(A)(2) and (B) - Priority: Time/Temperature Control for Safety Food, Cold Holding. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you.https://www.maricopa.gov/4576/AMC-Toolbox---Cold-Holding.

#33 — Proper Cooling Methods Used; Adequate Equipment for Temperature ControlPriority foundation4-301.11

Inspector's notes

1. Measeured the temperature of containers of tuna and deli meats being held at 47°F in the undercounter prep refrigerator in the front area. All TCS foods were removed from this refrigerator during the inspection. This unit must be repaired to maintain foods at 41°F or less. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation 4-301.11 - Priority Foundation: Cooling, Heating, and Holding Capacities-Equipment. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4617/AMC-Toolbox---Cooling.

#50 — Hot and Cold Water Available; Adequate PressureCounty code (MCEHC)
#51 — Plumbing Installed; Proper Backflow DevicesPriority5-202.13

Inspector's notes

1. The food prep sink is currently draining directly into the mop sink basin. The drain pipe for the food prep sink must not drain directly into the mop sink basin. Provide an NSF approved food prep sink that has an indirect , hard piped drain line that empties indirectly into a floor sink with a minimum 1 in. air-gap between the end of the drain pipe and the flood rim of the floor sink. 2. The middle and left compartmens of the three compartment sink are currently connected directly to the sewer system. Reroute the drain pipes from these two basins so that they empty into the floor sink with minimum 1 in. air gaps like the right compartment currently does. 3. Provide a rigid drain line for the sump pump that currently drains the condensate from the walk-in units into the floor sink below the 3-compartment sink. Ensure there is a 1-inch air gap between the end of the drain line and the flood rim of the floor sink. The drain line is currently extending down into the floor sink. Corrective Action: Correct prior to re-inspection.

Show full county text

Repeat Violation PRIORITY VIOLATION-5-202.13 - Priority: Backflow Prevention, Air Gap

#52 — Sewage and Waste Water Properly DisposedPriority5-402.13

Inspector's notes

1. The portion of the drain pipe for the three compartment sink that is directly connected to the sewer system is leaking onto the floor beneath the three compartment sink. All the basins for the three compartment sink must drain indirectly into the floor sink with minimum 1 in. air-gaps and the direct connection must be eliminated and properly capped off and sealed. Corrective Action: Correct prior to re-inspection.

Show full county text

PRIORITY VIOLATION-5-402.13 - Priority: Conveying Sewage

#56 — Adequate Ventilation and Lighting; Designated Areas UsedCore6-303.11

Inspector's notes

1. Replace the very dim light in the walk-in refrigerator. Corrective Action: Correct prior to re-inspection.

Show full county text

6-303.11 - Core: Intensity-Lighting

Feb 29, 2024Routine2 priority2 foundation1 coreC°

OC Inspection conducted with manager Sarah H. Establishment was open an operating. Inspection report emailed to Jen R.This establishment is not participating in the award program at this time and had 2 Priority, 2 Priority Foundation violations on this inspection.Correct all items on the report prior to reinspection on March 28th.***Observed a newly designed front service area with new equipment and new restrooms finishes. Establishment remodeled without prior approval from the Department. A Remodel permit will be required for this location.***Provide a floor sink for the pre sink. Prep sink can not drain into the mop sink basin. Food service and related sinks, and service (mop) sinks cannot receive the discharge of an indirect waste pipe. All drains must properly discharge into an approved sewer through a floor sink or floor drain MCEHC §8.1.8f).***Provide a 50-gallon water heater for the establishment. Current 38-gallon water heater is not approved (SPS-EH-2012-014).This establishment/operation has demonstrated sufficient compliance to proceed with the issuance of the permit. To complete the permitting process, issuance of this permit, and begin operation, the applicant must first submit payment of the annual operating permit fee to the Department’s Administrative Services. Fees paid up to this inspection approval do not include the annual operating permit fee. PAYMENT with a credit/debit card can be made via phone at 602-506-6824, Option 2. Per MCEHC Chapter I, Regs 4 & 5, no person shall conduct an operation or operate an establishment for which a permit is required without holding the necessary and valid permit to do so. Payment with a credit/debit card can be made on-line via select Pay a Fee at esd.maricopa.gov. Please note that if you select payment via online, the annual operating permit fee invoice may take up to 7 business days to post online. Also, checks and money orders are accepted via US Mail. If you select payment via US Mail, for further instructions please refer to the printed invoice. No operating permit is valid, until the permit fee is received by the Department. It is the responsibility of the permit holder/owner to notify MCESD if there are contact/ billing address changes.The Environmental Services Department will begin emailing permit card(s) and permit invoice(s) to permittees in the coming months. We need a current and accurate email address on file to ensure you receive a copy of your permit card and invoice(s) upon renewal.If you are unsure whether your email address is accurate, you may:• Contact your inspector using the phone number or email on your last inspection report to review, or• Contact the Department using the email addresses below,o Envquickservicerestaurants@maricopa.gov (facilities such as fast-food)o Envfullservicerestaurants@maricopa.gov (facilities that are full-service restaurants)o Envretailgrocery@maricopa.gov (facilities like grocery stores or retail food markets)o Envspecialtyprograms@maricopa.gov (mobile food/special events/plan review) Note: If you need to update your email address and/or other contact information, please submit an administrative change request form at the below website https://www.maricopa.gov/FormCenter/Environmental-Services-16/Administrative-Change-Request- Form-181 or call 602-506-6824.Please contact the Department to schedule a follow-up inspection at (602) 506 - 6980 once violations have been corrected. Please be advised that the New Business Permit Application fee includes one initial inspection and one follow-up inspection. Additional fees will be assessed for any additional follow-up plan review inspections.No County legal action will result from this inspection.Award: Not Participating,Signer: Sarah H.

#10 — Adequate Handwashing Sinks, Properly Supplied and AccessiblePriority foundation5-204.11

Priority Foundation-5-204.11, Pf: Handwashing Sinks - Location and Placement. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4573/AMC-Toolbox--- Handwashing. 1) Provide an approved NSF/ANSI hand sink in the back of house in view of the prep sink and 3-compartment sink. Must drain directly or to a floor sink. Correct By: Correct Prior To Reinspection

#22 — Proper Cold Holding TemperaturesPriority3-501.16

PRIORITY VIOLATION-3-501.16(A)(2) and (B), P: Time/Temperature Control for Safety Food, Cold Holding. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4576/AMC- Toolbox---Cold-Holding. 1) Observed cut tomatoes, tuna and steak with an internal temperature of 47- 51’F within the under counter cooler. PIC moved all TCS foods to the walk-in to properly cool. Do not store any TCS items in the under counter refrigerator until it has been repaired and holds an ambient air temperature of 41’F or below. Correct By: Corrected At Time Of Inspection

#33 — Proper Cooling Methods Used; Adequate Equipment for Temperature ControlPriority foundation4-301.11

Priority Foundation-4-301.11, Pf: Cooling, Heating, and Holding Capacities-Equipment. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4617/AMC-Toolbox--- Cooling. 1) Under counter refrigerator had an ambient air temperature of 47’F (see violation #20). Do not store any TCS items in the under counter refrigerator until it has been repaired and holds an ambient air temperature of 41’F or below. Correct By: Correct Prior To Reinspection

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-202.13

PRIORITY VIOLATION-5-202.13, P: Backflow Prevention, Air Gap 1) Provide an ASSE 1015 double check valve backflow preventer upstream of the proofer oven. Test and certify all backflow devices and provide the test report. 2) Provide an ASSE 1022 dual check valve backflow preventer upstream of the tea brewers. 3) Trim the riser on the 3-compartment sink so that it is below the bottom basin of the 3-compartment sink basin. Or reroute the wash and rinse drain lines to the floor sink and provide a 1-inch air gap above the floor sink (ensure floor sink goes through the grease trap). 4) Provide a rigid drain line for the sump pump drain draining into the floor sink below the 3-compartment sink. Ensure there is a 1-inch air gap between the end of the drain line and floor sink. Drain line is currently sitting inside of the floor sink. Correct By: Correct Prior To Reinspection

#55 — Physical Facilities Installed, Maintained, and CleanCore6-501.11

Core-6-501.11, C: Repairing-Premises, Structures, Attachments, and Fixtures-Methods 1) Replace burnt out lights throughout the back of the kitchen. Install a brighter light within the walk-in cooler. 2) Provide missing clean out covers. Correct By: Correct Prior To Reinspection