Score based on 5 scored inspections over the county's rolling 3-year window, weighted toward recent visits. How scoring works

93
Excellent

Glendale restaurant avg: 97

Compare with another

Score over time

100060202420252026Mar 6, 2024 — Routine — score 80 (1 priority, 1 foundation, 0 core)May 9, 2024 — Routine — score 100 (0 priority, 0 foundation, 0 core)Jan 16, 2025 — Routine — score 99 (0 priority, 0 foundation, 1 core)Jun 6, 2025 — Routine — score 83 (1 priority, 0 foundation, 2 core)Jan 8, 2026 — Routine — score 98 (0 priority, 0 foundation, 2 core)98
Score per routine inspection and re-inspection; dashed line marks the “Poor” threshold (60).

Inspection history5 on record

2026

Jan 8, 2026Routine2 coreA

Predefined Comment: No County legal action will result from this inspection.

#39 — Contamination Prevented during Food Preparation, Storage and DisplayCore3-307.11

Inspector's notes

Duct tape used to hold soda gun and line together. Instructed person in charge to remove tape as is a physical contamination hazard.

Show full county text

3-307.11 - Core: Miscellaneous Sources of Contamination

#55 — Physical Facilities Installed, Maintained, and CleanCore6-501.12

Inspector's notes

Floors and wall around kitchen fryer have heavy accumulation of grease. Instructed person in charge to clean area. 6-501.11 - Core: Repairing -Premises, Structures, Attachments, and Fixtures-Methods Addl Notes: Cove base by kitchen fryer has melted and exposed opening from cove base into wall. Instructed person in charge to repair area.

Show full county text

6-501.12 - Core: Cleaning, Frequency and Restrictions

2025

Jun 6, 2025Routine1 priority2 coreB

No County legal action will result from this inspection.Discussed requirements for bacon held at room temperature. Bacon must be cooked crispy to reduce water content.

#2 — Certified Food Protection ManagerCore2-102.12

Inspector's notes

No certified Food Manager was present at the time of inspection. In Compliance with the Food Code, Maricopa County requires a Food Manager present during operating hours. Emailed Maricopa Policy changes and additional resources on where to acquire a Food Manager Certification. Corrective Action: Correct prior to next routine inspection.

Show full county text

2-102.12(A) - Core: Certified Food Protection Manager. For a permanent fix to this violation, check out these resources on our website. https://www.maricopa.gov/5114/Food-Restaurants

#16 — Food-Contact Surfaces: Cleaned and SanitizedPriority4-501.114

Inspector's notes

Observed the three-compartment sink measuring at 25 PPM of chlorine. Alerted staff who re-dosed the sanitizer to the proper concentration at time of inspection. Re-educated on proper chlorine sanitizer levels (50-100 PPM). Discussed the importance of proper sanitizer levels and proper monitoring of sanitizer levels. Corrective Action: Corrected at time of inspection.

Show full county text

PRIORITY VIOLATION-4-501.114 (A-E) - Priority: Manual and Mechanical Warewashing Equipment, Chemical Sanitization- Temperature, pH, Concentration and Hardness. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4574/AMC-Toolbox---Food-Contact-Surfaces.

#47 — Food and Non-Food-Contact Surfaces Cleanable, Properly Designed, Constructed and UsedCore4-501.11

Inspector's notes

Observed a small leak from the large standing refrigerator. Staff stated a work order was already in for the equipment. All food was covered and protected from the leak at time of inspection. All equipment must be maintained in good repair at all times. Repair all equipment to a state of good repair prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.

Show full county text

4-501.11 - Core: Good Repair and Proper Adjustment-Equipment

Jan 16, 2025Routine1 coreA

No County legal action will result from this inspection.No cook today. Food was not offered today. Facility inspection conducted.

#55 — Physical Facilities Installed, Maintained, and CleanCore6-501.12

Inspector's notes

Observed heavy black and tan grease built up underneath the three-compartment sink and beside and behind the cook line. Grease was built up on the walls and had seeped between the wall and cove base. Staff to thoroughly clean and reattach the cove base securely to the walls. Staff stated the hood was scheduled to be cleaned by their third-party vendor this weekend. Physical facility must be cleaned frequently enough to prevent accumulation of dirt, organic matter, and food debris. Must clean physical facility prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.

Show full county text

6-501.12 - Core: Cleaning, Frequency and Restrictions

2024

May 9, 2024RoutinecleanA°

E&D, class 4 10+ seatingOC re-inspection was conducted with co-owner, Nick T. The establishment is open and operating.Most plumbing items had been addressed. A lot of facility items are still in working progress. Discussed with the owner, a minor remodel permit will be created to address all facility items.Permit is approved.Please address the following items in the remodel:1. Provide a reduced pressure zone assembly (ASSE 1013) at the water connection point of the mister system. Certify the backflow preventer and provide report.2. Seal gaps at wooden storage shelving unit then provide several coats of high-gloss paint (recommend in light color) on the wooden shelving and support beams.3. Provide additional lighting in the kitchen. Especially at the cookline. Light intensity in the food prep, cooking area must be at 50-foot candle.4. Remove large pots, pans and any large pieces of tools, wares that cannot fit inside the 3-comp sink .5. Detail clean areas under the hood, behind hood equipment and on the floor. There is a thick layer of grease and spilled foods on the floor. 6. Mount the grease collecting cup of the hood at the collecting port and not on the floor.7. Thaw out the reach-in freezer inside the dry storage room. This equipment has thick layer of ice inside the unit and its shelving.8. Disconnect the water line from the glass rinser or move the rinsing mechanism and plug the port.9. Repair/ replace the water heater inside the janitor closet. This water heater is to supply hot water for the hand sinks in the restrooms. Hot water took over 2 minutes to come to point of service.10. Replace the toilet seat with open front toilet seats in the men's and women's restrooms.Report is auto mailed to owner.A copy of the inspection rights is attached to the report.No County legal action will result from this inspection.Please contact the Department at 602-506-6824 to schedule the next inspection. Currently allow 7-15 business days to schedule.This establishment/operation has demonstrated sufficient compliance to proceed with the issuance of the permit. To complete the permitting process, issuance of this permit, and begin operation, the applicant must first submit payment of the annual operating permit fee to the Department’s Administrative Services. Fees paid up to this inspection approval do not include the annual operating permit fee. PAYMENT with a credit/debit card can be made via phone at 602-506-6824, Option 2. Per MCEHC Chapter I, Regs 4 & 5, no person shall conduct an operation or operate an establishment for which a permit is required without holding the necessary and valid permit to do so. Payment with a credit/debit card can be made on-line via select “Pay a Fee” at esd.maricopa.gov. Please note that if you select payment via online, the annual operating permit fee invoice may take up to 7 business days to post online. Also, checks and money orders are accepted via US Mail. If you select payment via US Mail, for further instructions please refer to the printed invoice. No operating permit is valid, until the permit fee is received by the Department. It is the responsibility of the permit holder/owner to notify MCESD if there are contact/ billing address changes.Manager / person in charge must be a certified food protection manager (CFPM). Please obtain and maintain on site for inspection purpose. Please be advised that the person in charge must be a CFPM and presence on site at all operational hours. Food handlers must maintain food handler’s certifications.:

Mar 6, 2024Routine1 priority1 foundationB°

E&D, class 4 10+OC inspection was conducted with the owner, Tito G. and bar manager, Rhonda. The establishment is open and operating.One of the staff is a certified food protection manager (CFPM). Please ensure the person in charge must be a CFPM and available at the site during all operational hours. Food service employees must have food handler certifications. Maintain all managers and food handlers’ certification on site for inspection purpose.Permit is approved.Please address the following items prior to the re-inspection on 4/5/24:1. Maintain the door between ice machine room and bar open, otherwise, provide a hand sink inside the ice machine room. Sink must have hot and cold water and side splash guards.2. Check the water heater for the restrooms. A recirculation pump can be installed to maintain hot water in the line. Hot water must be available at point of service within 45 seconds. Hot water took over 2 minutes to be at the hand sinks inside the restrooms.3. Provide FRP, stainless-steel or tiles backsplash behind and side of the mop sink closet. Backsplash must be from the floor to 24 inches above the top of the faucet.4. Provide 3/8” radius cove at walls and floor junctures inside the dry storage room.5. Detail clean inside/ outside of equipment and walk-in unit.6. Have the hood baffles clean.7. Flash off area around the hood vent with metal sheets.8. Seal gaps on wooden shelving units. Paint surface with semi-gloss paint or clear coat wood sealant. 9. Ensure ceiling tiles inside the ice machine room is washable.10. Remove ceiling fans inside the bar. Bladeless fans can be used inside the bar.11. Reseal all gaps in the hood and at hood and walls junctures.12. Caulk and seal all gaps, cracks, and penetrations throughout the facility. This includes inside the walk-in unit.13. Detail clean the facility from floor sinks, ceiling, walls, floor and inside/ outside of all equipment. There is accumulation of oil/ dirt/ grease/ grime on the floor in kitchen and bar.14. Refinish the floor in the kitchen and bar. Concrete floor is down to aggregate level. All gaps, expansion joint, cracks, gouges must be filled to the same level of the floor. Ensure smooth transition between floor and floor sink or should be flushed with it.15. Noted odor inside men’s room. Please clean or check exhaust vent. Repair/ replace as needed.16. Provide open front/ sanitary toilet seats for all of the toilets.No County legal action will result from this inspection.Auto emailed the report to the owner.This establishment/operation has demonstrated sufficient compliance to proceed with the issuance of the permit. To complete the permitting process, issuance of this permit, and begin operation, the applicant must first submit payment of the annual operating permit fee to the Department’s Administrative Services. Fees paid up to this inspection approval do not include the annual operating permit fee. PAYMENT with a credit/debit card can be made via phone at 602-506-6824, Option 2. Per MCEHC Chapter I, Regs 4 & 5, no person shall conduct an operation or operate an establishment for which a permit is required without holding the necessary and valid permit to do so. Payment with a credit/debit card can be made on-line via select “Pay a Fee” at esd.maricopa.gov. Please note that if you select payment via online, the annual operating permit fee invoice may take up to 7 business days to post online. Also, checks and money orders are accepted via US Mail. If you select payment via US Mail, for further instructions please refer to the printed invoice. No operating permit is valid, until the permit fee is received by the Department. It is the responsibility of the permit holder/owner to notify MCESD if there are contact/ billing address changes.Contact the Department at 602-506-6824 to schedule the next inspection. Allow 7-15 business days to schedule.Award: Not Participating,Email Sent: CHECKED,Signer: Gilberto Gomez

#25 — Consumer Advisory Provided for Raw or Undercooked FoodPriority foundation3-603.11

Priority Foundation-3-603.11, Pf: Consumption of Animal Foods that are Raw, Undercooked, or Not Otherwise Processed to Eliminate Pathogens. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4125/Food-SafetyOperator-Resources. __Correct the consumer advisory on the menu. Menu provided a disclaimer or consuming raw/ undercooked foods but does not provide a reminder on the menu items that the disclaimer is referring to. Please ensure that reminders and disclaimer must be on all forms of food/ drink menu. Correct By: Correct Prior To Reinspection

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-203.14

PRIORITY VIOLATION-5-203.14, P: Backflow Prevention Device, When Required ___ 1. Provide a reduced pressure backflow preventer (RPBP) (i.e.LF 009) at the water connection point of the soda carbonator. Conduits and fittings after the RPBP must be PEX or stainless steel. Provide a drain cup for the vent port of the device. Drainpipe must be rigid and indirectly discharge to the nearest floor sink with minimum 1” air gap from the finished floor. 2. Provide a RPBP at the water connection point of the glass rinser at the bar (or disconnect the water supply line to the glass rinser. Just shutting off the water supply line is not acceptable) and another RPBP at the water connection point of the mister system. 3. Certify the testable backflow preventers and provide reports. 4. Provide a hose bib vacuum breaker in between the faucet and the hose inside the mop sink. Please disconnect the hose inside the mop sink for the time being until the backflow preventer is installed. Correct By: Correct Prior To Reinspection