2026
Sep 15, 2026Routine1 coreA
No County legal action will result from this inspection.Reviewed spray bottle labeling.Discussed the atmospheric vacuum breaker (AVB) is,1. Intended for non-continuous pressure.2. Cannot have a shutoff/valve downstream of it.3. Is not appropriate for the higher-hazard cross-connection created by chemical dispensers.A county document further explaining chemical dispensers and other installations was included with the emailed report.
Inspector's notes
Observed chemical dispensing system connected downstream from the atmospheric vacuum breaker at the mop sink faucet. Shut-off devices, including chemical dispensing systems and spray nozzles, shall not be continuously installed downstream from an atmospheric vacuum breaker. Person in charge was advised to discontinue this configuration and connect the chemical dispensing system to an approved dedicated water line with appropriate backflow prevention. Repair plumbing to a state of good repair to provide appropriate backflow prevention. The chemical dispenser should be supplied by an approved dedicated water line, instead of the mop-sink faucet with the atmospheric vacuum breaker. This is the SECOND consecutive violation. Corrective Action: Correct prior to next routine inspection.
Show full county text
Repeat Violation 5-205.15 (B) - Core: System Maintained in Good Repair; Maintained
Apr 27, 2026Routine1 coreA
No County legal action will result from this inspection.
Inspector's notes
Observed chemical dispenser downstream from atmospheric vacuum breaker at mop sink. Discussed with person in charge placing a work order to have staff disconnect chemical dispenser from the vacuum breaker faucet to its own dedicated line. Observed unused water lines in mop sink area, suggested using one of these two lines. Shut-offs, including chemical dispensers and sprayer nozzles, are not approved for continuous installation downstream from atmospheric vacuum breakers. Must repair all plumbing to a state of good repair prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.
Show full county text
5-205.15 (B) - Core: System Maintained in Good Repair; Maintained
2025
Sep 18, 2025RoutinecleanA
Predefined Comment: No County legal action will result from this inspection.
Apr 23, 2025RoutinecleanA°
No County legal action will result from this inspection.
2024
Nov 13, 2024RoutinecleanA°
No County legal action will result from this inspection.
Nearby restaurants
Other places to eat within a short walk, with their current scores.
- 95Mr. Mesquite Street TacosB°445 N 99th Ave · 60 m away
- 92Freddy's Frozen Custard & SteakburgersB°405 Ne 99 Ave · 80 m away
- 100Bosa DonutsA355 N 99th Ave · 130 m away
- 99Burger KingA9920 W Van Buren St · 200 m away
- 94QuikTripB°297 N 99th Ave · 300 m away
- 100Dutch Bros CoffeeA9965 W Van Buren St · 350 m away
- 100Rally's # 4421A205 N 99th Ave · 400 m away
- 94KFC # D212131A10005 W Van Buren St · 400 m away
Data from Maricopa County Environmental Services public records, last checked Sep 22, 2026. Grades marked with ° are computed equivalents for establishments not participating in the county's voluntary grading program. View official county records →