100060202320252026Oct 17, 2023 — Routine — score 100 (0 priority, 0 foundation, 0 core)Dec 11, 2023 — Routine — score 62 (2 priority, 1 foundation, 3 core)Sep 30, 2025 — Routine — score 100 (0 priority, 0 foundation, 0 core)Jan 13, 2026 — Routine — score 100 (0 priority, 0 foundation, 0 core)100
Score per routine inspection and re-inspection; dashed line marks the “Poor” threshold (60).

Inspection history5 on record

2026

Jan 13, 2026RoutinecleanA

No County legal action will result from this inspection.

2025

Sep 30, 2025RoutinecleanA

Predefined Comment: No County legal action will result from this inspection.

Jun 17, 2025Advisorynot scoredclean

2023

Dec 11, 2023Routine2 priority1 foundation3 coreC°

This establishment is not participating in the award program at this time and had 2 Priority, 1 Priority Foundation and 3 Core Violations on this inspection.Inspection emailed to the store emailReinspection scheduled for Jan 2No County legal action will result from inspectionAward: Not Participating,Food Manager Licenses: 0,Review Complete: CHECKED,Review Notes: QA ML,Signer: Brinca Hernandez

#10 — Adequate Handwashing Sinks, Properly Supplied and AccessiblePriority foundation5-203.11

Priority Foundation-5-203.11, Pf: Handwashing Sinks-Numbers and Capacities. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4573/AMC-Toolbox---Handwashing.-- Facility has no handwash station in the back where ice is dispensed. Other handwash station around the corner and past the three compartment sink -- provide handwash station that is within 25ft, no physical barriers clearly visible from points of service Correct By: Correct Prior To Reinspection

#16 — Food-Contact Surfaces: Cleaned and SanitizedPriority4-501.114

PRIORITY VIOLATION-4-501.114, P: Manual and Mechanical Warewashing Equipment, Chemical Sanitization- Temperature, pH, Concentration and Hardness. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4574/AMC-Toolbox---Food-Contact-Surfaces. -- Quat ammonium sanitizer for the three compartment sink is below 150ppm. --- employee emptied quat ammonium sanitizer at time of inspection, educated on quat ammonium to be 150-400ppm as per manufacture specifications and utilizing test strips Correct By: Corrected At Time Of Inspection

#48 — Warewashing Facilities, Installed, Maintained, Used, Test StripsCore4-204.120

Core-4-204.120, C: Equipment Compartments, Drainage -- Facility has two drain plugs for the three compartment sink -- provide and utilize three drain plugs for the three compartment sink Correct By: Correct Prior To Next Routine Inspection

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-205.15

PRIORITY VIOLATION-5-205.15 (A), P: System Maintained in Good Repair; According to Law --- Drainage lines from the ice machine lay below the floor sink flood lip --- provide 1 inch air gap to the top of the floor sink flood for all drainage lines ASSE 1022 for the soda system is corroded -- provide ASSE 1013 reduced pressure zone backflow preventer with drainage port Mopsink atmospheric vacuum breaker leaks at the mopsink -- repair and maintain in good condition Correct By: Correct Prior To Reinspection

#52 — Sewage and Waste Water Properly DisposedCore5-403.12

Core-5-403.12, C: Other Liquid Wastes and Rainwater --- Floor sink at the soda system is not draining, standing water in the floor sink --- service and maintain in good condition, Walk in freezer has buildup of ice around the condensation line -- service and maintain in good repair Correct By: Correct Prior To Next Routine Inspection

#56 — Adequate Ventilation and Lighting; Designated Areas UsedCore6-303.11

Core-6-303.11, C: Intensity-Lighting -- Lighting in the walk in cooler. Lighting at 3 foot candles. --- Provide 20 foot candles as required in the walk in cooler Correct By: Correct Prior To Next Routine Inspection

Oct 17, 2023RoutineA°

OC re-inspection conducted with LacyReport emailed to Lacy and owner, Ryan M.Please be address the following within 30 days, or County legal action may resultNo County legal action will result from this inspection..

#1 — Plumbing and Backflow (FD PR)County code (MCEHC)

3. Provide ASSE 1013 reduced pressure zone backflow preventer with drainage line to the floor sink. 1 inch air gap required between backflow preventer and the drainage port along with bottom of the drainage line to the top of the floor sink flood lip 4. Install new ASSE 1022 inline dual check valve for the tea dispenser. Current ASSE 1022 is calcified :

#1 — Plumbing and Backflow (FD PR)County code (MCEHC)

1. Provide handwash station in the ice machine area. All work areas are to have a handwash station that is clearly visible, no physical barriers and within 25 ft. 2. Repair leak at the mopsink atmospheric vacuum breaker and drainage line under the three compartment sink wash basin, toilets 5. Provide 1 inch air gap for the ice machine drainage line to the top of the floor sink flood lip. Provide 1 inch air gap for the pre-rinser sprayer at the three compartment sink to the top of the flood lip 6. Provide drain plug for the middle basin of the three compartment sink 7. Provide floor drain covers in floor sinks :

#4 — Equipment (FD PR)County code (MCEHC)

8. Provide more light in the walk in cooler 9. Repair walk in freezer and remove ice buildup in walk in freezer 10. Chain gas tanks 11. Remove lid under the gas tanks 12. Resurface/remove rust in the walk in cooler :

#9 — Floors, Walls, Ceiling, and Finishes (FD PR)County code (MCEHC)

13. Seal all cracks, crevices and holes throughout --- under the toilets in the restroom, handwash station splash guards, mopsink, :

#15 — Other (FD PR)County code (MCEHC)

14. Clean facility, ie area behind hot water heater, sinks :