PlateScore

Luna Grill

B°

9317 E Ray Rd, Mesa 85212

Food Establishment - Eating & Drinking · Permit FD2504326

Score based on 2 scored inspections on record, weighted toward recent visits (one-year half-life). How scoring works

County record last checked Sep 22, 2026.

85
Good

Mesa restaurant avg: 93

Compare with another

Score over time

1000602026Feb 17, 2026 — Routine — score 85 (1 priority, 0 foundation, 0 core)Jul 7, 2026 — Routine — score 85 (1 priority, 0 foundation, 0 core)85
Score per routine inspection and re-inspection; dashed line marks the “Poor” threshold (60).

Inspection history2 on record

2026

Jul 7, 2026Routine1 priorityall corrected on siteB°

Predefined Comment: No County legal action will result from this inspection.**Talked to staff about water lines, drain covers, gyro meat cooking process and restroms.

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-202.11

Inspector's notes

Observed shut off nozzle attached to the hose still attached to the atmospheric vacuum breaker supplied mop sink. Hose was removed during service. Corrective Action: Corrected at time of inspection.

Show full county text

PRIORITY VIOLATION-5-202.11 (A) - Priority: Approved System and Cleanable Fixtures; According to Law Predefined Comment: PIC removed shut-off downstream from atmospheric vacuum breaker at time of inspection. Predefined Comment: Shut-offs, including chemical dispensers and sprayer nozzles, are not approved for continuous installation downstream from atmospheric vacuum breakers.

Feb 17, 2026Routine1 priorityall corrected on siteB

Predefined Comment: No County legal action will result from this inspection.**Talked to manager about hand sink techniques, hose types, food manager licenses and first aid kits. Added email to file from manager.

#51 — Plumbing Installed; Proper Backflow DevicesPriority5-205.12

Inspector's notes

Observed mop sink with atmospheric vacuum breaker is attached with a hose to the chemical system. Manager disconnected hose from the AVB mop sink. Corrective Action: Corrected at time of inspection.

Show full county text

PRIORITY VIOLATION-5-205.12 (A) - Priority: Prohibiting a Cross Connection; Drinking Lines Predefined Comment: PIC removed shut-off downstream from atmospheric vacuum breaker at time of inspection. Predefined Comment: Shut-offs, including chemical dispensers and sprayer nozzles, are not approved for continuous installation downstream from atmospheric vacuum breakers.

Nearby restaurants

Other places to eat within a short walk, with their current scores.

Data from Maricopa County Environmental Services public records, last checked Sep 22, 2026. Grades marked with ° are computed equivalents for establishments not participating in the county's voluntary grading program. View official county records →