PlateScore

Salvadoreno Restaurant

A

303 E Southern Ave, Mesa 85210

Food Establishment - Eating & Drinking · Permit FD-06525

Score based on 10 scored inspections over the county's rolling 3-year window, weighted toward recent visits. How scoring works

96
Excellent

Mesa restaurant avg: 93

Compare with another

Score over time

1000602023202420252026Aug 21, 2023 — Routine — score 68 (2 priority, 0 foundation, 2 core)Nov 30, 2023 — Routine — score 100 (0 priority, 0 foundation, 0 core)Apr 11, 2024 — Routine — score 97 (0 priority, 0 foundation, 3 core)Aug 9, 2024 — Routine — score 99 (0 priority, 0 foundation, 1 core)Nov 7, 2024 — Routine — score 99 (0 priority, 0 foundation, 1 core)Mar 3, 2025 — Routine — score 98 (0 priority, 0 foundation, 2 core)Jun 19, 2025 — Routine — score 100 (0 priority, 0 foundation, 0 core)Aug 26, 2025 — Routine — score 98 (0 priority, 0 foundation, 2 core)Feb 11, 2026 — Routine — score 85 (1 priority, 0 foundation, 0 core)Jun 10, 2026 — Routine — score 100 (0 priority, 0 foundation, 0 core)100
Score per routine inspection and re-inspection; dashed line marks the “Poor” threshold (60).

Inspection history11 on record

2026

Jun 10, 2026RoutinecleanA

Predefined Comment: No County legal action will result from this inspection.Predefined Comment: No violations noted at time of inspection.

Feb 11, 2026Routine1 priorityall corrected on siteB°

No County legal action will result from this inspection.Reviewed Time as a Public Health Control procedures with person in charge.

#21 — Proper Hot Holding TemperaturesPriority3-501.16

Inspector's notes

Observed cooked rice and chicken tamales being hot help but having internal temperatures of 110-125*F. Person in charge states these foods were placed to hot help less than an hour prior to the inspection. Except during preparation, cooking, cooling or when time is used as a control all TCS foods must be maintained at 135°F or above. All TCS foods improperly hot held were reheated to 165°F at time of inspection. Corrective Action: Corrected at time of inspection.

Show full county text

PRIORITY VIOLATION-3-501.16(A)(1) - Priority: Time/Temperature Control for Safety Food, Hot Holding. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4614/AMC-Toolbox---Hot-Holding.

2025

Dec 12, 2025Advisorynot scoredclean
Aug 26, 2025Routine2 coreA

Predefined Comment: No County legal action will result from this inspection.

#35 — Approved Thawing Methods UsedCore3-501.13

Inspector's notes

Some raw beef at 35 degrees F was thawing in cold water in the food-prep sink, but without being under cold-running water. The manager then put the meat in a container and put it under cold-running water. Corrective Action: Corrected at time of inspection.

Show full county text

3-501.13 - Core: Thawing

#39 — Contamination Prevented during Food Preparation, Storage and DisplayCore3-305.11

Inspector's notes

Two sacks of beans were stored directly on the floor in the storage area. Do not store food items directly on the floor. Corrective Action: Correct prior to next routine inspection.

Show full county text

3-305.11 - Core: Food Storage - Preventing Contamination from the Premises

Jun 19, 2025RoutinecleanA

Predefined Comment: No County legal action will result from this inspection.Predefined Comment: No violations noted at time of inspection.

Mar 3, 2025Routine2 coreA

No County legal action will result from this inspection.

#55 — Physical Facilities Installed, Maintained, and CleanCore6-201.11

Inspector's notes

Observed perforated acoustic ceiling tiles over kitchen and back prep areas above the ice machine and coolers. Observed flooring worn to aggregate in kitchen beneath the 3 comp sink. Observed a section of wall behind the food prep sink that has completely eroded through the drywall. Observed organic growth on the drywall. All floors, walls, and ceiling must be smooth and easily cleanable. Advised PIC to add FRP, stainless steel or equivalent to the wall to create a smooth and easily cleanable surface. Remove eroded drywall, replace and provide FRP or equivalent to create a smooth and easily cleanable surface. Must repair prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.

Show full county text

Repeat Violation *Fourth consecutive repeat violation* 6-201.11 - Core: Floors, Walls and Ceilings-Cleanability

#56 — Adequate Ventilation and Lighting; Designated Areas UsedCore6-501.14

Inspector's notes

Observed dust surrounding the overhead vents in the kitchen. Clean ceiling prior to the next routine inspection and maintain cleaned. Corrective Action: Correct prior to next routine inspection.

Show full county text

6-501.14 - Core: Cleaning Ventilation Systems, Nuisance and Discharge Prohibition

2024

Nov 7, 2024Routine1 coreA

No County legal action will result from this inspection.Discussed consumer advisory requirements with PIC. Observed multiple foods with a consumer advisory that are not offered raw or undercooked.

#55 — Physical Facilities Installed, Maintained, and CleanCore6-201.11

Inspector's notes

Observed perforated acoustic ceiling tiles over kitchen and back prep areas above the ice machine and coolers. Observed flooring worn to aggregate in kitchen beneath the 3 comp sink. All floors, walls, and ceiling must be smooth and easily cleanable. Advised PIC to add FRP, stainless steel or equivalent to the wall to create a smooth and easily cleanable surface. Must repair prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.

Show full county text

Repeat Violation *Third consecutive repeat violation* 6-201.11 - Core: Floors, Walls and Ceilings-Cleanability

Aug 9, 2024Routine1 coreA

No County legal action will result from this inspection.

#55 — Physical Facilities Installed, Maintained, and CleanCore6-201.11

Inspector's notes

Observed perforated acoustic ceiling tiles over kitchen and back prep areas above the ice machine and coolers. Observed flooring worn to aggregate in kitchen beneath the 3 comp sink. All floors, walls, and ceiling must be smooth and easily cleanable. Advised PIC to add FRP, stainless steel or equivalent to the wall to create a smooth and easily cleanable surface. Must repair prior to next routine inspection. Corrective Action: Correct prior to next routine inspection.

Show full county text

Repeat Violation *Second consecutive repeat violation* 6-201.11 - Core: Floors, Walls and Ceilings-Cleanability

Apr 11, 2024Routine3 coreA

This establishment received a(n) A Grade and had 0 Priority, 0 Priority Foundation violations on this inspection.Core-2-102.12(A), C: Certified Food Protection Manager ------ No certified food protection manager (CFM) available on site at the time of inspection. Discussed that a CFM must be available at all times to answer food safety questions for employees. Establishment currently has one CFM. Discussed that an additional CFM may be required. Discussed retaining records onsite for CFM and employee food handler certificates.Of note: Establishment has a consumer advisory on various seafood dishes including aguachile (shrimp) and tilapia. PIC stated these items are fully cooked with heat. Advised PIC to remove consumer advisory to prevent confusion. Provided Parasite Destruction Letter guidance document to PIC. Advised PIC if these items are offered raw/undercooked to provide the necessary parasite destruction letters from the supplier. A copy of the report was emailed to the manager.No County legal action will result from this inspection.On July 1st, 2023, the Environmental Services Department started emailing permit card(s) and permit invoice(s) to permittees. We need a current and accurate email address on file to ensure you receive a copy of your permit card and invoice(s) upon renewal. If you are unsure whether your email address is accurate, you may:• Contact your inspector using the phone number or email on your last inspection report to review, or • Contact the Department using the email addresses below, o Envquickservicerestaurants@maricopa.gov (facilities such as fast-food) o Envfullservicerestaurants@maricopa.gov (facilities that are full-service restaurants) o Envretailgrocery@maricopa.gov (facilities like grocery stores or retail food markets) o Envspecialtyprograms@maricopa.gov (mobile food/special events/plan review) If you need to update your email address and/or other contact information, please submit an administrative change request form at the below website https://www.maricopa.gov/FormCenter/Environmental-Services-16/Administrative-Change-Request-Form-181Award: A,Embargo Lbs: 0,Food Manager Licenses: 1,Signer: Enrique Beltran

#33 — Proper Cooling Methods Used; Adequate Equipment for Temperature ControlCore3-501.11

Core-3-501.11, C: Frozen Food ------ Observed various pre-packaged ice creams soft to the touch in the dessert chest freezer by the door. All foods held at 41*F or below. PIC relocated ice creams to the back freezer at the time of inspection. PIC discovered the unit had been placed on the warmest setting and had the unit turned lower. Advised PIC to ensure that frozen foods remain frozen solid upon returning to the chest freezer. Correct By: Corrected At Time Of Inspection

#51 — Plumbing Installed; Proper Backflow DevicesCore5-205.15

Core-5-205.15 (B), C: System Maintained in Good Repair; Maintained ----- Observed the 3 comp sink drain line extended below the flood rim of the floor sink. Discussed a 1" air gap is required above the floor sink. Correct prior to the next routine inspection. Correct By: Correct Prior To Next Routine Inspection

#55 — Physical Facilities Installed, Maintained, and CleanCore6-201.11

Core-6-201.11, C: Floors, Walls and Ceilings-Cleanability ------ Observed perforated acoustic ceiling tiles over kitchen and back prep areas above the ice machine and coolers. Observed flooring worn to aggregate in kitchen beneath the 3 comp sink. All floors, walls, and ceiling must be smooth and easily cleanable. Advised PIC to add FRP, stainless steel or equivalent to the wall to create a smooth and easily cleanable surface. Must repair prior to next routine inspection. Correct By: Correct Prior To Next Routine Inspection

2023

Nov 30, 2023RoutinecleanA

This establishment received a(n) A Grade and had 0 Priority, 0 Priority Foundation violations on this inspection.Copy of inspection provided to PIC via email.Notes:The Environmental Services Department will begin emailing permit card(s) and permit invoice(s) to permittees in the coming months. We need a current and accurate email address on file to ensure you receive a copy of your permit card and invoice(s) upon renewal.If you are unsure whether your email address is accurate, you may:• Contact your inspector using the phone number or email on your last inspection report to review, or• Contact the Department using the email addresses below,o Envquickservicerestaurants@maricopa.gov (facilities such as fast-food)o Envfullservicerestaurants@maricopa.gov (facilities that are full-service restaurants)o Envretailgrocery@maricopa.gov (facilities like grocery stores or retail food markets)o Envspecialtyprograms@maricopa.gov (mobile food/special events/plan review)Note: If you need to update your email address and/or other contact information, please submit an administrative change request form at the below websitehttps://www.maricopa.gov/FormCenter/Environmental-Services-16/Administrative-Change-Request-Form-181 or call 602-506-6824.No County legal action will result from this inspection.Award: A,Signer: Gloria Moreno

Aug 21, 2023Routine2 priority2 coreC°

This establishment is not participating in the award program at this time and had 2 Priority, 0 Priority Foundation violations on this inspection. Of note: -Establishment does not have a hand sink in the back storage and prep area where the ice machine in located and a prep area for processing raw vegetables. This area is also opened to customers who use the restroom. Advised PIC to discontinue allowing customers to use restroom and prep and storage areas cannot easily be blocked off. Advised PIC if a handwashing violation is observed in this area that a hand sink will be required. Advised PIC to use the main kitchen for vegetable prep. -PIC stated the owner is working with the landlord to address roof leaks and damaged ceiling tiles. Advised PIC to replace with the required vinyl tiles. This inspection was conducted with RS #1479.A copy of the report was emailed to the manager.No County legal action will result from this inspection.The Environmental Services Department will begin emailing permit card(s) and permit invoice(s) to permittees in the coming months. We need a current and accurate email address on file to ensure you receive a copy of your permit card and invoice(s) upon renewal.If you are unsure whether your email address is accurate, you may: • Contact your inspector using the phone number or email on your last inspection report to review, or• Contact the Department using the email addresses below, o Envquickservicerestaurants@maricopa.gov (facilities such as fast-food) o Envfullservicerestaurants@maricopa.gov (facilities that are full-service restaurants) o Envretailgrocery@maricopa.gov (facilities like grocery stores or retail food markets) o Envspecialtyprograms@maricopa.gov (mobile food/special events/plan review)Note: If you need to update your email address and/or other contact information, please submit an administrative change request form at the below website https://www.maricopa.gov/FormCenter/Environmental-Services-16/Administrative-Change-RequestForm-181 or call 602-506-6824Award: Not Participating,Embargo Lbs: 15,Food Manager Licenses: 2,Signer: Edi Beltran

#39 — Contamination Prevented during Food Preparation, Storage and DisplayCore3-305.11

Core-3-305.11, C: Food Storage-Preventing Contamination from the Premises ------ Observed broken ceiling tiles due to recent rain that had collapsed and was allowing water from the roof leak to splash on fresh, unwashed produce and on sealed boxes of containers. Advised PIC to ensure premises are not a source of contamination of food or food contact surfaces. Had PIC relocate produce and containers to another area where they could not become contaminated. Had PIC wash produce at the time of inspection. Correct By: Corrected At Time Of Inspection

#16 — Food-Contact Surfaces: Cleaned and SanitizedPriority4-602.11

PRIORITY VIOLATION-4-602.11, P: Equipment Food-Contact Surfaces and Utensils-Frequency. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4574/AMC-Toolbox---Food-Contact-Surfaces. ------ Observed the mechanical slicer stored overnight with visible cabbage and carrot food debris on the blade, shoot and pusher. The person in charge stated that those utensils had not been in use today. The person in charge had the slicer cleaned upon request. Discussed with the person in charge about cleaning equipment used with TCS foods every 4 hours or sooner. Correct By: Corrected At Time Of Inspection

#20 — Proper Cooling Time and TemperaturesPriority3-501.14

PRIORITY VIOLATION-3-501.14, P: Cooling. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4617/AMC-Toolbox---Cooling. ------ In the left reach in cooler in the main kitchen, observed a 5 gallon plastic container of cooling red salsa with internal temperatures ranging from 46-48*F when measured with a probe thermometer. Per date mark sticker, the salsa had been prepared yesterday and cooled overnight. Observed approximately 10 inches of cooling food. Observed the container stored on the lowest shelf. Ensure cooling from 135*F to 70*F is done in no more than two hours, and to 41*F or below in no more than four more hours. Cool most efficiently in shallow, uncovered pans in walk-ins, reach-ins or freezers. Since the salsa did not cool in the allotted 6 hours, the manager voluntarily discarded the improperly cooled salsa at the time of inspection (see embargo). Correct By: Corrected At Time Of Inspection

#55 — Physical Facilities Installed, Maintained, and CleanCore6-201.11

Repeat Violation Core-6-201.11, C: Floors, Walls and Ceilings-Cleanability ------ Observed perforated acoustic ceiling tiles over kitchen and back prep areas above the ice machine, veggie slicer and coolers. Observed flooring worn to aggregate in kitchen beneath the 3 comp sink that has been loosely covered with vinyl tiles. Observed rough painted walls behind the ice machine and veggie slicer/prep table in the back prep area. All floors, walls, and ceiling must be smooth and easily cleanable. Advised PIC to add FRP, stainless steel or equivalent to the wall to create a smooth and easily cleanable surface. Must repair prior to next routine inspection. Correct By: Correct Prior To Next Routine Inspection,Repeat Violations: 2nd